Rated Flange Default Creation Settings Tips

Rated Flange Default Creation Settings Tips

Last Updated: 2021.9

Material Data

The material data available to other components is now included in the Rated Flange window.

  • A new material default has been added for rated flange for both metric and customary units. Just as the other material defaults, this is located on the Materials tab under Tools > Defaults. It works the same way as the materials default for the other components. This default replaces both the material group default and the original material default for rated flange.
  • SA-105 is the default when the software is shipped.
  • The materials default for rated flange only allows selection of materials that are included in one of the following ASME references: B16.5 2003, B16.5 2009, B16.5 2013, B16.5 2017, B16.5 2020, B16.47 1996, B16.47 2006, B16.47 2011, B16.47 2017 and B16.47 2020.
  • The material search in the rated flange form only allows selection of materials that are included in the current active reference: B16.5 2003, B16.5 2009, B16.5 2013, B16.5 2017, B16.5 2020, B16.47 1996, B16.47 2006, B16.47 2011, B16.47 2017 and B16.47 2020.
  • Due to the material changes, designs patched from 2012.0 or an earlier version of DesignCalcs will not have a material set; in most cases the math can still run as the Material Group will still be set.

Default Settings

a screenshot of the Defaults user interface general tab with ASME flange fields highlighted

  • If the size is 24” or less and the host is a shell, head, reducer, or nozzle, the default type will be set to the selection in the ASME Flange Type field on the General tab under Tools > Defaults.
  • If the size is 24” or less and the host is a flange, the default type will be set to Blind.
  • If the size is greater than 24” and the host is a shell, head, reducer, or nozzle, the default type will be set to Weld Neck Series A or B based on the selection in the ASME Flange Series field on the General tab under Tools > Defaults.
  • If the size is greater than 24” and the host is a flange, the default type will be set to Blind Series A or B based on the selection in the ASME Flange Series field on the General tab under Tools > Defaults.

Flange Size

  • If the size of the host is less than or equal to ½”, the size will be ½”.
  • If the size of the host is over 58”, the size will be 60”.
  • If the size of the host falls on a rated flange size included in the B16 references, the flange will default to that size.
  • If the size of the host falls between sizes included in the B16 references,the flange will default to the larger of the two sizes.

Flange Class

Upon creation of a rated flange, DesignCalcs will attempt to find the optimal flange class. If an optimal rated flange cannot be determined, the flange will start at class 150.



Related content

Rated Flange Methodology
Rated Flange Methodology
More like this
Appendix 2 Flange - Load/Bolt Calcs
Appendix 2 Flange - Load/Bolt Calcs
More like this
Release Notes
Release Notes
Read with this
Rated Flange - Design Info
Rated Flange - Design Info
More like this
How To Set Up Multi-factor Logins for CEI, Finglow, and PRG Software
How To Set Up Multi-factor Logins for CEI, Finglow, and PRG Software
Read with this
External Loads on Rated Flanges
External Loads on Rated Flanges
More like this