ProWrite 2023.10.0.5814 Release Notes
Build 2023.10.0.5814
Release Status - October 24, 2023
During installation, if an issue occurs with the Sentinel Run-Time Environment Installer, cancel the install and go to Installing or Updating the Windows Driver for the Hasp License for steps on how to complete a sentinel hasp installation. Once this is completed, install ProWrite again.
For users with some OS versions, the following error message is displayed:
You can address this issue by going to Microsoft Edge WebView2 | Microsoft Edge Developer, downloading the Evergreen Bootstrapper, and running the installer.
For a quick demo of the updates listed below, watch the following video:
New Features
The following updates have been made to account for 2023 ASME Section IX code updates:
A new option for the 2023 code year is now available in all documents within the software (S9). (PWN-8361)
The 2023 base and filler materials have been added to the Base Metal database within the software (S9).(PWN-8642)
The passes per side variable requirements for supplementary essential and nonessential variable situations depending on meeting certain criteria have been adjusted in the software (S9). (PWN-8698)
The current/polarity variable requirements for supplementary essential and nonessential variable situations depending on meeting certain criteria have been adjusted in the software (S9). (PWN-8687)
A restriction has been added so that WPQs limit 1 process per each fillet weld qualification; groove welds can still qualify 1-3 processes (S9). (PWN-8753)
The ASME Section VIII and Section IX PWHT Hold Times Notes have been updated to account for the changes to Section VIII in the software (S9). (PWN-8620)
The essential variable requirement on F-No. for corrosion resistant overlay has been removed in the software (S9). (PWN-8676)
The nonessential variable requirement for transfer mode for GMAW and FCAW documents has been added in the software (S9). (PWN-8801)
The bead width field on PQRs and WPSs has been added and can now be documented for essential variable requirements (S9). (PWN-8653;8664)
Issues Resolved
You can now delete and enter new continuity entries as expected in the software (S9). (PWN-5351)
The D1.1 preheat temperature temperature and interpass temperature settings now work as expected. Previously, a message was displayed noting that the code was outdated (D1). (PWN-8567)
You can now edit the AWS Classification for corrosion resistant overlay WPSs as expected (S9). (PWN-8828)
How to Update ProWrite:
Enterprise users:
Apply the database schema updates in order:
136 upgrade from 135
137 upgrade from 136
Note:
If you are updating ProWrite versions older than 2023.7, refer to the ProWrite 2023.7.0.5652 Release Notes for the SQL scripts to update the enterprise database.
Notify all users, close all connections, and backup your database.
Update the application.
LocalDB users:
Once you update the application, the software automatically updates the database when you open it.
Cloud Users:
The update has automatically been applied. No action is necessary.