ProWrite 2022.3.0.4797 Release Notes
Build 2022.3.0.4797
Release Status was March 30, 2022
If an issue occurs during the install, when trying to lay down the Sentinel Run-Time Environment Installer, please cancel the install and follow the Sentinel Hasp Installation steps in the article below. Once this has completed, run the ProWrite install again:
Installing or Updating the Windows Driver for the Hasp License
New Features
Added the ability to modify the mentioning of Thermal Processes per QW-410.64 (PWN-5410)
Improved the scaling/size functionality amongst several windows (PWN-6020)
Performance improvements for large datasets (PWN-6937)
Expanded Welder/WPS Analysis to include Corrosion Resistant Overlay and Hardface Overlay (PWN-6981)
Expanded the Associations button on PQR, WPS, WPQ, and Welders to allow association to Groups (PWN-6938)
Improvement for adding images to the database and documents (PWN-3146)
Issues Resolved
Added limitations to image size uploaded into ProWrite to prevent database slowness (PWN-3146)
Resolved issue with WPS Thickness consolidation and selecting additional supporting PQRs (PWN-6761)
Improved the pop-up message on WPQs to clarify what fields need to be addressed (PWN-7056)
Resolved issue with Logos printing on documents (PWN-7152)
Resolved issue with Procedure Submittals and printing of notes and signature lines (PWN-6936)
Resolved issue with Procedure Submittals Summary page and WPS Quick Reference reports order of WPSs (PWN-7032)
Resolved issue with filler metals with SFA Number of 5.20 where 0 was dropped off (PWN-7215)
Resolved issue with Associations not being retained when copying documents (PWN-7235)
2021 Section IX Code Changes
Added PWHT Temps for 2021 Section I WPSs when using P-No. 1 and P-No. 3 (PWN-6764)
Added PWHT Temps for 2021 Section I WPSs when using P-No. 4 (PWN-6790)
Added PWHT Temps for 2021 Section I WPSs when using P-No. 5A and 5B (PWN-6815)
Added PWHT Temps for 2021 Section I WPSs when using P-No. 6 (PWN-6865)
Added PWHT Temps for 2021 Section I WPSs when using P-No. 7 (PWN-6890)
Added PWHT Temps for 2021 Section I WPSs when using P-No. 15E (PWN-6840)
Added Metric PWHT Temps for 2020 B31.1 code updates (PWN-4999)
Added Metric Preheat Temps for 2020 B31.1 code updates (PWN-4984)
Added Metric Max Interpass Temps for 2021 B31.1 code updates (PWN-5030)
Steps to update:
For Enterprise:
Apply the database schema updates in order:
123 upgrade from 122
124 upgrade from 123
Notify all users, close all connections, and backup your database
Update the application
LocalDB users:
Update the application and the software will update the database for you when you open it
Cloud Users:
No action necessary, it has been updated by CEI