Cone to Cylinder Failure Modes

Cone to Cylinder Failure Modes

First Added: 2022.3

Internal Pressure

Alpha: The half-apex angle exceeds the scope limit per Appendix 1-5. The limit is 30°.
Q: The value of Q is negative and is therefore out of scope per Appendix 1-5.
Reinforcement: The required reinforcement exceeds the available reinforcement.

 

External Pressure

Alpha: The half-apex angle exceeds what is in scope per Appendix 1-8. The limit is 60°.

tr: The junction is not designed as a line of support and the cone tr (ext P) < shell tr (ext P). See UG-33(f).
Q: The value of Q is negative and is therefore out of scope per Appendix 1-8.
Reinforcement: The required reinforcement exceeds the available reinforcement.

 

Line of Support

A: The value of A could not be returned from the external pressure chart.

B: The value of B required, exceeds the maximum B on the external pressure chart.

F: The value of F is negative and is therefore out of scope per Appendix 1-8.

Ring Location: The ring centroid or a part of the ring is too far from the junction.

Inertia: The inertia of the ring by itself (if present) is insufficient and the inertia of the combined ring-shell-cone section is insufficient.

Temperature: The temperature for external pressure exceeds the max temperature of one or more of the external pressure charts required.

 

Related content

DesignCalcs 2022.3 Release Notes
DesignCalcs 2022.3 Release Notes
Read with this
Cone to Cylinder - General Info
Cone to Cylinder - General Info
More like this
Seismic Methodology: ASCE 7-98 and Forward
Seismic Methodology: ASCE 7-98 and Forward
Read with this
Cone to Cylinder - Results
Cone to Cylinder - Results
More like this
Pipe Fittings and Long Weld Necks Dimensional Data
Pipe Fittings and Long Weld Necks Dimensional Data
Read with this
Cone to Cylinder - Stiffening Ring
Cone to Cylinder - Stiffening Ring
More like this