General
Label for "WPQ No.": Replaces the WPQ No. designation throughout the program with the entered text.
Field value for "Deposited weld metal range qualified": When there is no limit to the welder’s deposited weld metal thickness, the range qualified can be set to display ‘Max to be Welded,’ ‘WPS Limits’ or ‘Unlimited’ on the WPQ.
Treat GMAW and FCAW as the same process for ASME welder qualification: Because of the similarities between the two processes, ASME Section IX allows a welder to be qualified for both GMAW and FCAW processes when they qualify in one of the processes. Some companies prefer to keep the qualifications separate for quality control purposes. Clear this box to require a welder to qualify for each of these processes individually. When checked a welder must have a WPQ for both the FCAW and the GMAW processes for expiration to then be the later of either for both processes. This option is not available for AWS D1.1.
An example for the above:
A welder has a GMAW WPQ with a weld date of 1/1/2017.
That welder also has a FCAW WPQ with a weld date of 1/2/2017.
Assume a 6 month expiration window without the use of qualification (i.e. WPQ document) expiration.
With the box checked the welder expires for both processes on 7/2/2017.
With the box unchecked the welder expires for the GMAW on 7/1/2017 and the FCAW processes on 7/2/2017.
WPQ Expiration Exception Report
The Expiration Exception Report’s function is to notify the person running any WPQ reports of expired welders. The default behavior can be set to "Do nothing," or "Show exception report," or "Skip WPQ and show exception report."
Mechanical Test Label
The ASME Section IX Code suggested WPQ form, QW-484, contains a field with a prompt of "Mechanical tests conducted by." However, when qualifying a standard groove weld, many companies will choose to radiograph the groove joint instead of doing the bend tests and may want to document the name of the lab which performed the radiographic tests.
Always use "Mechanical tests conducted by": The program will always use mechanical tests on both the input screen and the report regardless of whether bend or radiographic tests were used.
Change to "Volumetric tests conducted by": If bend tests are used on the input screen, the label on the input screen and on the report will show "Mechanical tests conducted by," otherwise it will use "Volumetric tests conducted by."
Always use "Mechanical/ Volumetric tests conducted by": - Selecting this option will allow the program to always use mechanical/ volumetric tests on both the input screen and the report regardless of whether bend or volumetric tests were used.
Welder Image
User Welder Image on WPQ Output: Select this box to display the welder's image on their WPQ.
Top Margin: Indicate how far the welder's image will appear from the top of the WPQ document.
Right Margin: Indicate how far from the right hand side of the WPQ document the welder's image will appear.
Related articles