Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Flange Dimensions

Weld 42: The weld leg of the studded outlet perimeter weld.

Weld 44: The weld leg of the studded outlet weld at the finished opening of the host shell.

Diameter of Reinforcement: The limit of reinforcement measured parallel to the studded outlet axis. This is a calculated value determined per UG-40(b). The result may be reduced by the user, but it may not be increased beyond what is calculated per UG-40(b). Reducing the value results in a lower available area in the reinforcement calculations and makes meeting UG-37 reinforcement requirements more difficult. For example, openings in close proximity may not have overlapping limits of reinforcement, so the code would require a reduction in this value and would thereby increase the difficulty of meeting UG-37 requirements. See UG-42 for more information.

 