Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

Bolt Size: The diameter of the bolt shaft. This field will be automatically completed if a bolt is selected from the Bolt Search.

Threads Per Inch: The number of threads per inch on the bolt shaft. This field will be automatically completed if a bolt is selected from the Bolt Search.

Nominal Diameter: The nominal diameter of the bolt. This field will be completed automatically if the Bolt Search is used to select the bolts.

Root Area: The bolt root area based on the smallest diameter on the bolt. This field will automatically be completed if the Bolt Search is used to select the bolts.

Number of Bolts: The actual number of bolts, not the number of bolt holes.

Bolt Circle: The diameter of the circle that passes through the center of each bolt.

Distance across flats of bolting nut: Enter the distance measured across the flats of the bolting nut.

Ultimate 28 day concrete strength: The theoretical concrete strength after at least 28 days of setup. This value will be multiplied by the concrete factor on the Wind/Seismic tab under Tools > Defaults to determine the allowable concrete strength.

Anchor Bolt Material

Material: A brief description of the component material. When the material selection dialog is used, the default description is based on settings on the Materials-Misc. tab under Tools > Defaults. For example, if the settings are for Spec and Type/Grade and the material is SA-516 Grade 70, this field will show SA-516 Gr. 70. If the settings are instead just for Spec, the field will show SA-516. The field may be edited by the user to say anything without breaking the relationship to the material database; while this flexibility can be very helpful, the user must take care to enter correct information.

Condition: A brief description of the component material. Similar to the "Material" field, the description will default a certain way based on settings on the Materials-Misc. tab under Tools > Defaults when the material selection is used. This field may be edited by the user without breaking the relationship to the material database. As with the “Material” field, the user must take care to enter correct information.

Density: The material density based on table PRD from Section II, Part D. For those materials that did not have a clear match in this table, every effort was made to assign conservative values. Manually editing this field will sever the connection to the material in the database as indicated by the "Unlisted Material" caption.

Stress (Hot): The material allowable stress at the base ring temperature. When a 3.5:1 safety factor is specified in the vessel screen, this value comes from Section II, Part D (Table 1A for Ferrous Materials, Table 1B for Non-Ferrous Materials, and Table 3 for Bolting). If a 4:1 safety factor is specified, this value is calculated based on the ultimate strength from Table U in Section II, Part D; furthermore, the value is limited to the values listed in the allowable stress tables for yield and creep governed cases. In cases where the base ring temperature exceeds the highest temperature entry for this material’s stress line, the value will be zero. Manually editing this field will inform the software that the user is defining the material differently than what is stored in the database and the connection to the material in the database will be severed. This is indicated by the “Unlisted Material” caption.

Stress (Cold): The material allowable stress at 70 °F (20 °C). When a 3.5:1 safety factor is specified in the vessel screen, this value comes from Section II, Part D (Table 1A for Ferrous Materials, Table 1B for Non-Ferrous Materials, and Table 3 for Bolting). If a 4:1 safety factor is specified, this value is calculated based on the ultimate strength from Table U in Section II, Part D; furthermore, the value is limited to the values listed in the allowable stress tables for yield and creep governed cases. Manually editing this field will sever the connection to the material in the database as indicated by the “Unlisted Material” caption.

 


  • No labels