Build 2018.0.0.548

Release status was December 19th, 2017


New Features

  • ASME Section VIII, Division 2 calculations will start are being rolled out over the next several releases.
  • Rated Flanges are now an option for Division 2 vessels.  The weld details options still refer to Section VIII, Division 1 UW-21.  DC-94

Issues Resolved

  • Resolved an issue where the UG-32(j) check was based off of inside diameter instead when the user selected to input the head ID instead of OD.  DC-1012
  • Resolved an issue where the warning popup that occurs for the UG-32(j) check was appearing multiple times, this was reduced to one time for most cases.  DC-1345
  • Resolved an issue where the Division 2 cylinder internal pressure math was returning incorrect results in some cases.  This only occurred in the release candidate 2017.2.  DC-1344, DC-1348
  • Resolved an issue where DesignCalcs would not wait long enough for the FEPipe engine to launch from the nozzle form.  This only occurred in the release candidate 2017.2.  DC-1363

Miscellaneous

  • Updated some of the controls in the studded outlet form.  DC-846