Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Updated title.

Last Updated: 2021.9

Configuration

Description: The label given for the component. It will appear in the component pane, the report dialog, the summary pane, and at the top of the component report. This will default to the component type and component number. For example, the third nozzle for the vessel will start with a description of Nozzle 3.  Selecting a fitting on the Design Info tab, will fill in this field; but the description can still be overwritten by the user.

...

Nozzle Configuration: Select the basic nozzle attachment configuration from the drop-down menu.

Nozzle Location

The following fields only affect the 3D drawing; they do not have an effect on the calculations or the output.

Distance from Reference Line: For nozzles in cylindrical shells, this indicates the distance from the reference line datum measured along the axis of the vessel. For nozzles in nozzles, this is the axial distance of the second nozzle from the first nozzle's intersection with its host. For example, if a cylindrical nozzle is attached to a cylindrical shell and a second nozzle is attached to the cylindrical nozzle, the distance from reference line will be the distance from the axis of the second nozzle to the location where the cylindrical nozzle intersects the shell.

Distance from Center of Head/Flange: This indicates the distance from the center of the head or flange to where the nozzle axis pierces the inside surface; the distance is measured parallel to the axis of the head or flange and does not indicate direction.

Nozzle Orientation: Determines the position of the nozzle around the component. Vertical vessels in the standard view will show a nozzle at 0° on the front of the vessel, 90° on the right side of the vessel, and so on. Horizontal vessels in the standard view will show a nozzle at 0° on the top of the vessel, 90° on the back of the vessel, and so on. The angle is determined based on where the nozzle axis penetrates the inside surface of the host.

...

Reference UG-44(a) with UG-45: Checking this box will add reference to UG-44(a)  in the summary section on the first page of the nozzle report and also in the nozzle neck thickness calculation section on the second page of the nozzle report.


...

Filter by label (Content by label)
showLabelsfalse
max5
spacesCKB
showSpacefalse
sortmodified
reversetrue
typepage
cqllabel = "nozzle" and label = "designcalcs" and type = "page" and space = "CEIKB"
labelsdesigncalcs vessel components shell tube jacket heat-exchanger

...