Image RemovedLast Updated: 2020.5


Image Added

Include File Path: This checkbox will print the exact file path for the vessel file in the report.

...

Full: This will update the Nameplate Information of the Cover page section of the report. 

Construction Type(s) and Services(s)

Arc or Gas Welded: This will update the Nameplate Information of the Cover page section of the report under the Construction Types with W, for code years 2017 and earlier.

Pressure Welded except Resistance: This will update the Nameplate Information of the Cover page section of the report under the Construction Types with P, for code years 2017 and earlier.

Brazed: This will update the Nameplate Information of the Cover page section of the report under the Construction Types with B, for code years 2017 and earlier.

Resistance Welded: This will update the Nameplate Information of the Cover page section of the report under the Construction Types with RES, for code years 2017 and earlier.

Lethal ServiceLow Temperature Service: 

Services(s)

This will update the Nameplate Information of the Cover page section of the report under the Construction Types with ULT, for code years 2019 and later. 

Tensile Enhanced by heat treat: This will update the Nameplate Information of the Cover page section of the report under the Construction Types with UHT, for code years 2019 and later. 

Layered: This will update the Nameplate Information of the Cover page section of the report under the Construction Types with WL, for code years 2019 and later. 

GraphiteThis will update the Nameplate Information of the Cover page section of the report under the Construction Types with G, for code years 2015 and later. 

Low Temperature ServiceCold StretchedThis will update the Nameplate Information of the Cover page section of the report under the Construction Types with CS, for code years 2019 and later. 

...

Lethal Service

...

NeitherThis will update the Nameplate Information of the Cover page section of the report under Special Type with L.

Neither: This is the default option for the firing type of the vessel and this selection will not print anything to the cover pageEither this or Unfired Steam Boiler or Direct Firing may be selected.

Unfired Steam Boiler: Either this or Neither or Direct Firing may be selected.  This will update the Nameplate Information of the Cover page section of the report under Special Type with UB. 

Direct Firing: Either this or Neither or Unfired Steam Boiler may be selected.  This will update the Nameplate Information of the Cover page section of the report under Special Type with DF.

Restrict printing of Construction Types and Services on Cover Page based on Code Year: If this check box is checked, the printing of the characters, to the Cover Page, will work as described above.  If this check box is not checked, the printing of the characters above will ignore the year selection. This check box will be set to unchecked by default for all vessels created before the 2020.5 release and will be checked by default for all new vessels.

National Board Data Reports

...