During installation, if an issue occurs with the Sentinel Run-Time Environment Installer, cancel the install and go to Installing or Updating the Windows Driver for the Hasp License for steps on how to complete a sentinel hasp installation. Once this is completed, install DesignCalcs again.
For a quick demo of the updates listed below, watch the following video:
New Features
DesignCalcs now exports to AutoCad Inventor. These features DC-8828, DC-9118
Note |
---|
Note: |
...
DesignCalcs now supports lifting lugs on heads . This is currently supported for the following head types: hemispherical, torispherical, ASME flanged and dished (F&D, ) and ellipsoidal. DC-7788
DesignCalcs is rolling out improvements and expansions The following enhancements have been applied to the wind and seismic calculations. In this release the :
The seismic inputs for Fa and Fv
now determine seismic loads based on the user input or the greater values from the Seismic tables. Previously, these inputs were only used to fill in
gaps in the building codes for the more severe site classes E and F, where the values were not provided.
Therefore, the Fa and Fv values for vessels
within older versions are now set to zero for site classes A, B, C and D
as well as new vessels; values from
older versions are set for site classes E and F.
DC-8966
Note |
---|
Note: DesignCalcs uses the greater of the input or values determined by the tables in the building codes |
...
. This update affects building codes for 1998 and later. |
...
DesignCalcs now includes ASME B16.11 2021 code changes have now been adopted in the software. For DesignCalcs this specifically affected . DC-9041
Note |
---|
Note: The latest code changes specifically affect 9000# socket weld coupling thickness in millimeters and how the software handles these values. For more information, see the Pipe Fittings and Long Weld Necks Dimensional Data page. |
...
Issues Resolved
...
When running a Zick Analysis, if more than one liquid row is input, the software recognizes the inputs as though only one row exists, and calculate based on the max depth and max liquid density of all rows. If multiple entries exist, an increase in the vessel weight for the operating condition calculations can occur. Previously, multiple liquid inputs for horizontal inputs were resulting in a low liquid weight, which made results unconservative. DC-8871
Miscellaneous
The message when When closing a leg Leg form, now recommends a NozzlePRO Analysis. Future integrations are planned. the following message is now displayed: Please check the localized stresses. NozzlePRO analysis is recommended. DC-9105
A new License Information option under within the help Help menu has been added called License Information. This allow you , which allows users to see your licenses , and their location and expiration date information. DC-8906
The DesignCalcs manual is no longer installed by available or displayed in the software. It is several years out of date and the online Instead, users can access CEI’s learning management system, Think Tank Academy, and the knowledge base should be used insteadthe https://training.thinkcei.com/ and the CEI Knowledge Base. DC-539