Last Updated: 20192021.59

Configuration

Description: The label given for the component. It will appear in the component pane, the report dialog, the summary pane, and at the top of the component report. This will default to the component type and component number. For example, the third nozzle for the vessel will start with a description of Nozzle 3.  Selecting a fitting on the Design Info tab, will fill in this field; but the description can still be overwritten by the user.

...

Groove Location: Determines the groove well depth label on the report.

Consider Insert for Reinforcement Calculations If Applicable: Checking this box will consider the part of the nozzle neck inserted past the outside of the host wall for UW-16.1(k) and Partial Penetration configurations. The consideration takes place in the area of reinforcement calculations.  This checkbox defaults as unchecked.

Reference UG-44(a) with UG-45: Checking this box will add reference to UG-44(a)  in the summary section on the first page of the nozzle report and also in the nozzle neck thickness calculation section on the second page of the nozzle report.


...

Filter by label (Content by label)
showLabelsfalse
max5
spacesCKB
showSpacefalse
sortmodified
reversetrue
typepage
cqllabel = "nozzle" and label = "designcalcs" and type = "page" and space = "CEIKB"
labelsdesigncalcs vessel components shell tube jacket heat-exchanger

...