(Fixed, Floating, and U-Tube)

Calculate Welds Using: Select the desired weld design equations. To consider the expanded tube length in lending strength at the joint, select Appendix A.

Joint Type: Only applicable to Appendix A joints; see Appendix A for more information.

Weld Configuration: Select the weld configuration. For Appendix A calculations, the options in this field are dependent upon the type of joint selected.

Weld Type: Select whether the weld is Full Strength, Partial Strength, or Seal. This only applies to calculations per UW-20.

Fillet Leg: The length of the fillet weld leg.

Design Strength: Applies to UW-20 partial strength welds. This value will be compared with the axial tube strength (Ft) and the lower value will be used in the calculations.

Groove Leg: The length of the groove weld leg

Use qualification test efficiency: Select whether or not to use the qualification test efficiency. This only applies to Appendix A joints.

Joint Efficiency Factor: Reduces the strength of the joint for the calculations. See Table A-2 for more information.

 