New Features
- Studded Outlet calculations will now take advantage of the seamless equivalent feature if applicable. The 2015 Edition of the code introduced this in the UG-37 reinforcement calculations. For 2015 and newer vessels, the studded outlet material and the host material will both determine if they need a seamless equivalent (this applies to welded product forms that have a built in 85% joint efficiency for their allowable stress).
If the material needs a seamless equivalent, DesignCalcs will attempt to find one based on a matching protocol - see Seamless Equivalent Criteria. If a seamless equivalent is found, the reinforcement math will use the allowable stress from the seamless equivalent. If a seamless equivalent could not be found, the allowable stress will instead be divided by 0.85. This code change favors a more economical design. DC-437
Issues Resolved
- An issue was resolved that was preventing all of the Temerature/Ultimate Strength pairs from showing in the material viewer. DC-484
- An issue was resolved that was causing errors to be thrown during nozzle report creation for nozzles that were using custom materials and had lost connection to the custom material. DC-575
- An issue was resolved that was causing the extreme fiber elongation calculations from showing the head forms. The may update the status on some heads. DC-535
- Removed an outdated reference to UG-45(c) in the nozzle form under Unit Stresses on the Weld Paths tab and also in the nozzle report under the same section. The reference was repaced with just UG-45. DC-579
- An issue was resolved that would cause an exception to occur if a WRC analysis was copied several times after WRC reports were run. DC-516
- An issue was resolved that was preventing the correct status from showing up in certain cases for heads that triggered the Appendix 1-4(f) calculations. DC-481
- Fixed some issues with the head copy to prevent multiple "left", "right", "top", or "bottom" heads to exist. DC-804, DC-806
Miscellaneous
- Several improvements have been made to the online knowledge base.
- The copyright was updated to 2017. DC-763