Rated Flange - MDMT/Misc

First Release: 2021.6

Other Calculations

Perform UCS-66 calculations: Selecting this check box will cause the software to perform UCS-66 toughness calculations on the component. This option is only available to materials that are classified as UCS materials per Table UCS-23.

Exemption Drop-down: When UCS-66 calculations will not be performed (the software will not allow these calculations when a non-UCS material is used), an exemption must be entered. The exemption may be typed in or selected from the drop-down options, but the user is responsible for ensuring that the exemption selected is valid for the material, service, etc., in question.

tg: The governing thickness used for MDMT calculations. This is determined using the minimum flange thickness and the host thickness. This field can be changed by the user.

MDMT Reductions

Take UCS-66(b) Reduction: Selecting this check box will take advantage of the reduction in allowed MDMT per UCS-66(b). This paragraph includes a calculation for the component which compensates for any excess material thickness in the component.

Apply UCS-68(c): Selecting this check box will give an additional flat reduction in the allowed MDMT per UCS-68(c). Carefully review this paragraph as there are steep requirements for this exemption.

MDMT

MDMT Pressure: The net internal pressure (concave side) on the component coincident with the minimum design metal temperature (MDMT). This includes static head.

MDMT Curve: The notes in Figure UCS-66 provide the criteria to assign the MDMT curve to the material and product form of the component. Curve A will give the least favorable allowed MDMT and Curve D will give the most favorable allowed MDMT. When UCS materials do not have a clear match using the criteria, they are assigned a conservative value of A. As the software cannot currently obtain possible improvements in curve rating due to heat treatment and other factors, the user may override the curve value.