Build 2023.10.0.5810
Release Status - October 17, 2023
During installation, if an issue occurs with theĀ Sentinel Run-Time Environment Installer, cancel the install and go to Installing or Updating the Windows Driver for the Hasp License for steps on how to complete a sentinel hasp installation. Once this is completed, install ProWrite again.
For users with some OS versions, the following error message is displayed:
You can address this issue by going to https://developer.microsoft.com/en-us/microsoft-edge/webview2/#download-section, downloading the Evergreen Bootstrapper, and running the installer.
For a quick demo of the updates listed below, watch the following video:
https://fast.wistia.com/embed/medias/jnv5kl9ofs.jsonp
2023 Section IX Code Changes
Added drop downs to all documents for access to the 2023 Code year (S9) (PWN-8361)
Added, revised, and updated 2023 base and filler materials to the base metal database. (S9) (PWN-8642)
Adjusted passes per side variable requirements for supplementary essential and nonessential variable situations depending on meeting certain criteria. (S9) (PWN-8698)
Adjusted current/polarity variable requirements for supplementary essential and nonessential variable situations depending on meeting certain criteria. (S9) (PWN-8687)
Added a restriction WPQs that limit 1 process per each fillet weld qualification. Groove welds can still qualify 1-3 processes. (S9) (PWN-8753)
Updated the Section VIII and Section IX PWHT Hold Times Notes for the changes to Section VIII. (S9) (PWN-8620)
Removed the essential variable requirement on F-No. for corrosion resistant overlay. (S9) (PWN-8676)
Added nonessential variable requirement for transfer mode for GMAW and FCAW documents. (S9) (PWN-8801)
Added bead width field to PQRs and WPSs to be documented for essential variable requirements. (S9) (PWN-8653/8664)
Issues Resolved
An issue with the deletion of continuity entries and entering a new continuity entry preventing the deleted continuity entry remaining deleted was resolved. (S9) (PWN-5351)
An issue with the D1.1 preheat temperature temperature and interpass temperature pop-up message being outdated was resolved. (D1) (PWN-8567)
An issue with the ability to edit the AWS Classification for corrosion resistant overlay WPSs was resolved. (S9) (PWN-8828)
How to Update ProWrite:
Enterprise users:
Apply the database schema updates in order:
136 upgrade from 135
137 upgrade from 136
Note:
If you are updating ProWrite versions older than 2023.7, refer to the ProWrite 2023.7.0.5652 Release Notes for the SQL scripts to update the enterprise database.
Notify all users, close all connections, and backup your database.
Update the application.
LocalDB users:
Once you update the application, the software automatically updates the database when you open it.
Cloud Users:
The update has automatically been applied. No action is necessary.