- The data is taken from the native dimensions provided by the document.
- Socket Weld Coupling dimensions come from Table 6.1-2 for Metric and Table I6.1-2 2C for Customary
- Threaded Coupling dimensions come from Table 6.1-5 for Metric and Table I6.1-5 5C for Customary
- When multiple options are provided, the most conservative is used in the standard data.
- For Socket Weld couplings, the Socket Bore Dia. B max value is provided as the diameter in the standard data.
- For Socket Weld couplings, the Socket Wall Thickness C min value is provided as the thickness in the standard data.
- For Threaded couplings, the inside diameter is assumed as the outside diameter of the same NPS from ASME B36.10M in the standard data.
- For Threaded couplings, the wall thickness is calculated as one half of the difference of the outside diameter D from B16.11 and the outside diameter from B36.10M.
...