The following document contains the intensive updates and features regarding the PRG June 2022 release.
Features and Modifications | Section |
| 1 |
NozzlePRO Integration Features
| 2 |
ASME Section VIII, Div 2 Part 5 Compliance Features
| 3 |
4 | |
Updating Buckling Guidelines for Nozzles, Branches, and Pipe Shoes
| 5 |
Cumulative Damage â TES Calculations | 6 |
Improvements to Modeling Welds Fillet Overreach Model Construction Guidelines and Elements | 7 |
| 8 |
| 9 |
10 | |
| 11 |
Nonlinear Elastic Plastic Solver Features
| 12 |
...
Users needing to find the exact region node distribution of the regions can consider the following procedure:
7 , 1 'psi' 0.1000000E+01 'in.' 0.1000000E+01 'lb.' 0.1000000E+01 'lbm' 0.2590080E-02 4 -3, 7 0.9625000E+02,0.1250000E+00,0.2940000E+08,0.3000000E+00 0., 1. 0.0000000E+00,0.0000000E+00,0.0000000E+00 0.0000000E+00, 0.0000000E+00, 0.1000000E+01 0.7549790E-07, 0.1000000E+01, 0.0000000E+00 1, 2, 3, 4, 5, 6, 7 'Pad/Header at Junction' 0.2530000E+05 0.2940000E+08 7005218. 0.1000000E+01 T 0.7000000E+02 0.2230000E+05 0.3340000E+05 0.6940001E-05 0.2940000E+08 T 0.3750000E+00 7 0.0000000E+00 0.0000000E+00 'Branch at Junction' 0.2000000E+05 1005526. 0.1000000E+01 T 0.7000000E+02 0.2000000E+05 0.3080000E+05 0.6940001E-05 0.2950000E+08 T 0.3750000E+00 7 0.0000000E+00 0.0000000E+00 'Branch Transition' 0.2000000E+05 1005526. 0.1000000E+01 T 0.7000000E+02 0.2000000E+05 0.3080000E+05 0.6940001E-05 0.2950000E+08 T 0.3750000E+00 7 0.0000000E+00 0.0000000E+00 'Pad Outer Edge Weld' 0.2530000E+05 7005218. 0.1000000E+01 T 0.7000000E+02 0.2230000E+05 0.3340000E+05 0.6940001E-05 0.2940000E+08 T 0.3750000E+00 7 0.0000000E+00 0.0000000E+00 'Header Outside Pad Area' 0.2530000E+05 0.2940000E+08 7005218. 0.1000000E+01 T 0.7000000E+02 0.2230000E+05 0.3340000E+05 0.6940001E-05 0.2940000E+08 T 0.3750000E+00 7 0.0000000E+00 0.0000000E+00 'Branch removed from Junction' 0.2950000E+08 1005526. 0.1000000E+01 T 0.7000000E+02 0.2000000E+05 0.3080000E+05 0.6940001E-05 0.2950000E+08 T 0.3750000E+00 7 0.0000000E+00 0.0000000E+00 'Pad removed from Junction' 0.2940000E+08 7005218. 0.1000000E+01 T 0.7000000E+02 0.2230000E+05 0.3340000E+05 0.6940001E-05 0.2940000E+08 T 0.3750000E+00 7 0.0000000E+00 0.0000000E+00 | 7 regions Units used Data for SIFs, kâs and SSIs Region Numbers IN ORDER Region #1 Region #2 Region #3 Region #4 Region #5 Region #6 Region #7 |
Plot the model from anywhere. When the static model generator displays the model: (panel at right) Enter File:Keyboard May need to read the regions: The set the point size so that it is easy to see: point_radius, 3 | |
Then enter the region that should be plotted: draw, region, 1 This will show all nodes in the model that are considered in region #1. The regions are prioritized from left to right as shown above in yellow. PAD/HEADER AT JUNCTION Find the regions that are of interest in the model. Taken from the region file: | |
'Pad/Header at Junction' 'Branch at Junction' 'Branch Transition' 'Pad Outer Edge Weld' 'Header Outside Pad Area' 'Branch removed from Junction' 'Pad removed from Junction' | |
Header outside pad area. |
Pad Modifications
In the case that users want to take credit for only half of the entered pad, there is an option for this in rft28.t that allows for modifications.
...