Release: 2020.1.0.3137
Important: Enterprise users will need to contact support for a apply all database upgrade scriptscripts attached below. LocalDB users may proceed to install 2020.1.0.3137. Cloud is already up-to-date.
Performance Improvements
Add the ability to run a report of all WPQs for multiple welders at once (S9, D1) (PWN-1305)
Added ability to edit P Number 1 in WPSs when code assistance is disabled. (S9) (PWN-1521)
Added ability to edit Range Qualified fields in Non-Code Assisted WPQs. (S9) (PWN-1423)
Added ability to edit P# field to S# or M# in all Non-Code Assisted welding docs. (S9) (PWN-1437)
Added ability to override Weld Type in all Non-Code Assisted welding docs. (S9, D1) (PWN-1479)
Added ability to override Method in all Non-Code Assisted welding docs. (S9, D1) (PWN-1493)
Added ability to override Process in all Non-Code Assisted welding docs. (S9, D1) (PWN-1507)
Added ability to override Product Form in all Non-Code Assisted PQRs. (S9, D1) (PWN-1451)
Added ability to override Construction Code in all Non-Code Assisted PQRs. (S9, D1) (PWN-1465)
Added popup window for "license troubleshooting" when license is expired. (S9, D1) (PWN-1815)
Add Badge Number field to welder’s page. (S9, D1) (PWN-2143)
Created ability for users to specify location of newly added PDF Database Storage(S9, D1) (PWN-1972)
Changed User defined weld process input from case sensitive to case insensitive. (S9, D1) (PWN-1932)
Added Custom Report Designer for Custom WPS reports (PWN-2264)
Updated notification to include welders expiring in 60 days (S9, D1) (PWN-1622, PWN-2000)
...
Resolved issue of Welder Expiration Notification monthly email not sending (S9, D1) (PWN-2298)
Resolved issue of the Role of Foreman not attaching for local database users (S9, D1) (PWN-1805)
Resolved issue of the Install not writing over existing PW folder during upgrade (S9, D1) (PWN-1881)
Updated documents to 2019 from 2017 to show appropriate code year. (S9) (PWN-1791)
Updated ProWrite’s edition and copyright years in the About Screen. (S9, D1) (PWN-1857)(PWN-1942)
Resolved schema update for issue in cloud when processing schema version 101 (S9, D1) (PWN-1921)
Resolved issue of Security button not being enabled for cloud users (S9, D1) (PWN-2236)
Resolved user defined process issue of entering existing user defined processes. (S9, D1) (PWN-1932)
Resolved Empty string password issue (S9, D1) (PWN-1911)(PWN-2226)
Resolved issue of errors due to the existence of duplicate User Defined Processes (S9, D1) (PWN-2409)
Resolved issue of Stud weld throwing an error when attempting to create a WPQ (S9) (PWN-3115)
Resolved issue of not being able to create WPQ Templates (S9) (PWN-3095)
Additional Codes
Added Basic Essential Variable Checking. (Additional Codes) (CRTN-3123)
Steps to update:
For Enterprise:
Notify all users, close all connections, and backup your database
Apply the database schema updates in order:
Update the application
LocalDB users:
Update the application and the software will update the database for you when you open it
Cloud Users:
No action necessary, it has been updated by CEI