(Fixed, Floating, and U-Tube)
Several of these fields will be automatically completed based on the host tube information when the Custom Tube Browser is used. The content of those fields will be locked.
...
Ap: Total area on the tubesheet that is enclosed by the step-wise perimeter, Cp.
Cp: Perimeter Perimeter of the tube layout measured in stepwise increments from center-to-center of the outer-most tubes. See figure UHX-12.2 or figure 4.18.14 for reference.
Pattern: Select whether the hole pattern is an equilateral triangle or a square.
...
(Ttm): The mean tube temperature along the tube length as expected during operation; this considers the entire tube bundle. It is generally not conservative to substitute the tube design temperature for Ttm.
...