New Features

The following updates have been made to account for 2023 ASME Section IX Code Changes

...

code updates:

  • A new option for the 2023 code year (S9) is now available to access in all documents within the software (S9). (PWN-8361)

  • Added, revised, and updated The 2023 base and filler materials have been added to the base metal database. Base Metal database within the software (S9).(PWN-8642)

  • Adjusted The passes per side variable requirements for supplementary essential and nonessential variable situations depending on meeting certain criteria . have been adjusted in the software (S9). (PWN-8698)

  • Adjusted The current/polarity variable requirements for supplementary essential and nonessential variable situations depending on meeting certain criteria . have been adjusted in the software (S9). (PWN-8687)

  • Added a restriction WPQs that A restriction has been added so that WPQs limit 1 process per each fillet weld qualification. Groove ; groove welds can still qualify 1-3 processes . (S9). (PWN-8753)

  • Updated the The ASME Section VIII and Section IX PWHT Hold Times Notes have been updated to account for the changes to Section VIII . in the software (S9). (PWN-8620)

  • Removed the The essential variable requirement on F-No. for corrosion resistant overlay . has been removed in the software (S9). (PWN-8676)

  • Added The nonessential variable requirement for transfer mode for GMAW and FCAW documents . has been added in the software (S9). (PWN-8801)

  • Added The bead width field to on PQRs and WPSs to has been added and can now be documented for essential variable requirements . (S9). (PWN-8653/;8664)

Issues Resolved

  • An issue with the deletion of continuity entries and entering a new continuity entry preventing the deleted continuity entry remaining deleted was resolved. You can now delete and enter new continuity entries as expected in the software (S9). (PWN-5351)

  • An issue with the The D1.1 preheat temperature temperature and interpass temperature pop-up message being outdated was resolved. settings now work as expected. Previously, a message was displayed noting that the code was outdated (D1). (PWN-8567)

  • An issue with the ability to You can now edit the AWS Classification for corrosion resistant overlay WPSs was resolved. as expected (S9). (PWN-8828)

How to Update ProWrite:

...