Last Updated: 20202021.09


(Fixed, Floating, and U-Tube)

Calculate Welds Using: Select the desired weld design equations. To consider the expanded tube length in lending strength at the joint, select Appendix A.

...

Weld Configuration: Select the weld configuration. For Appendix A calculations, the options in this field are dependent upon the type of joint selected.  UW-20 configurations were expanded in 2021 to add e partial strength, f full strength and f partial strength; the software allows these three new options for all code years.

Appendix A Configurations have changed their denotation over the years.  In 2021, (f) and (g) swapped and the option to pick (b-1) was removed.  The software shows the 2021 configurations regardless of the year selected for the vessel.  The table below shows the 2021 equivalents to the older years.

Appendix A Configuration Equivalents

2021 or Later2019 - 20152013 - 2010
Fig. A-2(a)Fig. A-2(a)Fig. A-2.1
Fig. A-2(b)Fig. A-2(b)Fig. A-2.2
Fig. A-2(c)Fig. A-2(c)Fig. A-2.3
Fig. A-2(d)Fig. A-2(d)Fig. A-2.4
Fig. A-2(e)Fig. A-2(e)Fig. A-2.5
Fig. A-2(f)Fig. A-2(g)Fig. A-2.7
Fig. A-2(g)Fig. A-2(f)Fig. A-2.6
Fig. A-2(h)Fig. A-2(h)Fig. A-2.7
Fig. A-2(i)Fig. A-2(i)Fig. A-2.8


Weld Type: Select whether the weld is Full Strength, Partial Strength, or Seal. This only applies to calculations per UW-20.

...